Eight Protocols, Compared

What each protocol is for, how it connects, and how IoTServa reads it.

Six teal cables of different thicknesses converging into one small white hub

The Eight, Side by Side

ProtocolBest ForMediumRangeData ModelIoTServa Reads It Via
BACnet HVAC and building plant IP networks (BACnet/IP over UDP, BACnet/SC over secure WebSocket) or RS-485 (MS/TP) Building and campus LAN Objects with properties: Analog Input, Analog Value, Binary, Multi-state, Schedule, Trend Log BACnet/IP on your LAN, or MS/TP through an RS-485 gateway
Modbus Meters, drives and PLCs RS-485 or RS-232 (RTU), Ethernet port 502 (TCP) Plant floor and switch room Four tables: coils, discrete inputs, input registers, holding registers RS-485 serial or Ethernet port 502
KNX Lighting, blinds and rooms Twisted pair (TP), KNX IP, KNX RF A building or campus, with areas and lines linked over KNX IP Group addresses (for example 1/2/5) carrying typed datapoints (DPT) A KNX IP interface or router
DALI Luminaire status and emergency tests Two-wire bus carrying power and data, read through a DALI gateway or controller Up to 300 m between the furthest devices on 1.5 mm2 cable, per DALI line Control gear (drivers) and control devices (sensors, buttons), addressed by short address, group and scene A DALI gateway or controller, over its BACnet, Modbus, KNX or MQTT interface
Serial Bus Legacy and serial-only equipment Serial cable: shielded twisted pair for RS-485, point-to-point for RS-232 RS-485: about 1200 m at 100 kbit/s or lower, shorter at higher speeds. RS-232: about 15 m by the standard, longer at low baud rates on good cable A master polls devices by address, one request at a time; the electrical layer carries the bytes, a protocol on top gives them meaning An RS-485 or RS-232 port on the edge gateway
MQTT Moving data between systems TCP and TLS (port 8883), WebSocket Anywhere with IP reachability Topic strings with free-form payloads such as JSON or plain values Your broker, as a client
LoRa Low-power sensors over distance Sub-GHz radio to a gateway, then IP backhaul Kilometres in open terrain, less indoors Small uplink frames on a port, decoded by a payload decoder Your LoRaWAN network server or gateways
BLE Tags and short-range sensors 2.4 GHz radio to a BLE gateway, then IP backhaul Metres to tens of metres indoors (Bluetooth 5 Coded PHY reaches further in open line of sight) Advertising data, or GATT services and characteristics BLE gateways in the premises

Choosing, Answered

Which protocol should I start with?

Start with the protocol of the equipment that matters most on site. Most pilots begin with one wired protocol and one wireless one, then add the rest.

Can one project use all eight protocols?

Yes. Protocols are drivers inside the same project, and every reading ends up in the same tag model.