Guides for Mixed-Protocol Projects
Short, practical articles from the engineers who read these protocols every day.
BACnet vs Modbus: Which Protocol Fits Which Job
BACnet and Modbus both run buildings and plants, but they model data differently. Compare their networks, discovery and addressing, and see where each fits.
Read the Guide
KNX vs BACnet in Buildings: Rooms Versus Plant
KNX controls rooms and BACnet controls plant. See how group addresses differ from BACnet objects, how each is secured, and why hotels and offices run both.
Read the Guide
LoRaWAN in Malaysia: AS923 Plan Explained
Learn why Malaysia uses the AS923 LoRaWAN plan, what to confirm with suppliers before you buy gateways and sensors, and how airtime limits battery life.
Read the Guide
Modbus Register Maps: Addresses, Word Order, Scaling
A Modbus reading is only as good as its register map. Learn the 40001 address offset, word order and scaling mistakes that give plausible but wrong values.
Read the Guide
MQTT Topic Naming for Multi-Site IoT Projects
A consistent MQTT topic scheme saves years of pain on multi-site projects. See a simple convention, what to avoid, and how QoS and retained messages fit in.
Read the Guide
BLE vs LoRa for Sensors: Range, Power and Use Cases
BLE and LoRa both suit battery sensors but at very different ranges. Compare range, power, data and infrastructure to choose for rooms, sites or both.
Read the Guide
Modbus to MQTT: Publishing Register Values as Topics
How to turn Modbus registers into MQTT topics: polling, decoding scale and word order, topic and payload design, QoS, retained values and failure handling.
Read the Guide
Modbus RTU vs Modbus TCP: Wiring, Addressing, Speed
Compare Modbus RTU over RS-485 with Modbus TCP over Ethernet: wiring and termination, device addressing, speed, converters and when to choose each.
Read the Guide
LoRaWAN Gateway Placement: Height, Antenna, Backhaul
Where you put a LoRaWAN gateway decides coverage. Learn about height, line of sight, antennas, backhaul and how to test with a real sensor before rollout.
Read the Guide
Alert Rules for Silent IoT Sensors and Low Batteries
A threshold alert cannot see a dead sensor. Learn rules for missing data, low battery, weak signal and rate of change, with delays that avoid false alarms.
Read the Guide
Energy Sub-Metering with Modbus: Setup Guide
Read Modbus energy meters and inverters with consistent units, correct scaling and a balance check against the main incomer, for tenants, lines and solar.
Read the Guide
DALI vs KNX for Lighting Control: How They Differ
DALI addresses single luminaires on a two-wire lighting bus, while KNX controls whole rooms and building functions. See the differences and how to read both.
Read the Guide
DALI Gateway Integration: Reading Lighting Data Safely
How a DALI gateway exposes luminaire data over BACnet, Modbus, KNX or MQTT, what DALI-2 and D4i add, and how to read it without overloading the bus.
Read the Guide
DALI Emergency Lighting Monitoring and Test Records
Automatic tests on DALI emergency luminaires can report function and duration results. Learn how to collect them as dated records and alert on failures.
Read the Guide
RS-485 Wiring Best Practices: Cable, Termination, Biasing
Daisy-chain topology, 120 ohm termination, bias resistors, shielded twisted pair, grounding and length limits. Get the RS-485 trunk right before the software.
Read the Guide
RS-485 vs RS-232 vs RS-422: Choosing a Serial Standard
RS-232 is single-ended point-to-point, RS-422 is one driver to several receivers, and RS-485 is a multidrop bus. Compare range, device counts and uses.
Read the Guide
Modbus RTU Troubleshooting: Timeouts, CRC Errors and Silence
Work through serial settings, addresses, wiring, termination and timing when a Modbus RTU device does not answer or keeps returning damaged frames.
Read the Guide
MQTT QoS, Retained Messages and Last Will Explained
Quality of service 0, 1 and 2, retained messages and Last Will in plain terms, with practical guidance for sensor, gateway and alarm telemetry on MQTT.
Read the Guide
BACnet MS/TP vs BACnet/IP: Which One You Have and Why
MS/TP is token passing over RS-485 and BACnet/IP runs over Ethernet on UDP port 47808. Learn the differences, the role of a BBMD and how to read both.
Read the Guide
KNX ETS Project Import: Getting Named Group Addresses
Why the ETS project is the only source of meaning for KNX group addresses, what an export contains and how to turn it into named, typed tags.
Read the Guide
BACnet COV vs Polling: When to Subscribe and When to Ask
Change of value subscriptions reduce traffic but have limits. Learn when COV helps, when polling is safer and how to size either on MS/TP and BACnet/IP.
Read the Guide
LoRaWAN Battery Life and Airtime: Making Sensors Last
How report interval, spreading factor and payload size decide battery life and airtime, and how to set each of them so field sensors last for years.
Read the GuideBLE Beacons for Asset Tracking: What Works Indoors
How Bluetooth Low Energy beacons and gateways locate assets, what zone-level accuracy really means, and how to plan gateways and tags indoors.
Read the Guide
Cold Room Temperature Monitoring: Sensors and Alerts
Where to place temperature sensors in a cold room, how often to read them, how to alert without false alarms from door openings, and what records to keep.
Read the Guide
Data Quality in IoT: Why a Stale Reading Is Worse Than a Gap
What good, stale and bad quality flags mean, how store and forward keeps history honest during outages, and why dashboards should never repeat an old value.
Read the GuideNeed a Definition?
The glossary explains COV, DPT, QoS, AS923 and the rest in a sentence or two.