IoTServa Request a Pilot
IoT Platform for Buildings and Plants

Six Protocols.
One IoT Platform.

BACnet, Modbus, KNX, MQTT, LoRa and BLE devices, read, normalized and put to work from one place.

A DIN-rail IoT gateway at the centre of an open building control cabinet, field cables running in from both sides and teal status lights glowing
Wired and Wireless Together One Tag Model Edge, On-Premise or Cloud Open REST and MQTT Output Read-Only Mode per Site

6

Protocols read natively: BACnet, Modbus, KNX, MQTT, LoRa and BLE

1

Tag model, so a temperature looks the same whichever protocol sent it

3

Ways to deploy: on an edge gateway, on your own server, or in the cloud

4

Ways to use the data: dashboards, alerts, rules and an open API


Most sites run at least three of these protocols side by side. IoTServa exists so that the people who need the data do not have to learn all of them.

Every System Speaks
Its Own Dialect.

A chiller, a power meter, a hotel room and a tank sensor can all measure temperature or energy. Each one describes it in a different way, so combining them usually means a different tool per protocol.

  • One place to look. Every device appears in the same list with the same names and units.
  • No re-wiring. Devices stay on the protocol they already use.
  • Nothing to translate by hand. Scaling, byte order and datapoint types are handled once per device model.
BACnet

Object analog-input 3, property present-value.

Modbus

Holding register 40012, two words, word-swapped.

KNX

Group address 1/2/5, datapoint type 9.001.

MQTT

A topic string and whatever payload the vendor chose.

LoRa

A few bytes on a port, decoded by a payload decoder.

BLE

A GATT characteristic or an advertising packet.

Many Addresses In. One Tag Out.

Pick a protocol to see how a native address becomes a named, typed tag.

BACnet

Read chillers, air handlers and VAV boxes over BACnet/IP and BACnet MS/TP, with COV subscriptions so changes arrive when they happen.

Native address

Device 1204
analog-input,3
present-value
units: degrees-celsius

Normalized tag

site.tower-a.ahu-02.supply-air-temp

13.4°C

Sample addresses are illustrative. Real tag names follow your site, building and equipment naming.

Read the BACnet Page

Connect. Normalize. Act.

Three jobs, done once, whichever protocol a device speaks.

Connect

Native drivers talk to each device the way it expects, on the network it is already on. Discovery finds what is there, profiles describe what it means.

  • BACnet
  • Modbus
  • KNX
  • MQTT
  • LoRa
  • BLE

Normalize

Every reading becomes a tag with a name, a unit, a timestamp and a quality flag, placed in your site, building and equipment hierarchy.

  • Name
  • Unit
  • Timestamp
  • Quality

Act

Show it, alert on it, trend it, automate with it, or hand it to another system. The same tag drives all of them.

  • Dashboards
  • Alerts
  • Rules
  • API

See the Platform Architecture

Prove It Before You Commit

A pilot reads your real devices against written criteria. Then you decide.

See the Pilot Process

Scope

Agree what the pilot must prove, and on which devices.

Connect

Drivers and profiles set up against your real equipment.

Prove

Readings checked against known values in real operation.

Decide

Results measured against the criteria. You choose the next step.

Deployment

Your Data Stays Where You Put It.

Run protocol drivers on a gateway at the site, keep history on your own server, or use the cloud. You choose, and you can mix.

  • Edge gateway. Drivers run beside the equipment, so a lost uplink does not stop collection.
  • On-premise server. History, dashboards and users stay inside your network.
  • Cloud. One place for many sites, with TLS and per-site access.

How We Protect It

Close-up of a DIN-rail IoT gateway with RS-485 terminals, an Ethernet cable and a small antenna, teal status lights lit

Questions, Answered.

The short version of what people ask before a pilot.

More Questions

What is IoTServa?

IoTServa is an IoT platform that reads devices speaking BACnet, Modbus, KNX, MQTT, LoRa and BLE, turns every reading into one consistent tag model, and puts the data to work in dashboards, alerts, rules and an open API.

Which protocols does IoTServa support?

BACnet (IP and MS/TP), Modbus (RTU and TCP), KNX (through KNX IP), MQTT (as a client of any broker), LoRaWAN uplinks, and Bluetooth Low Energy through BLE gateways.

Do I have to replace my existing devices or BMS?

No. IoTServa reads the devices and systems you already run. It sits beside your BMS, PLCs and gateways rather than replacing them.

Where does IoTServa run?

At the edge on a gateway or industrial PC, on a server in your own premises, or in the cloud. Many sites use an edge gateway for protocol work and a server for history and dashboards.

Can IoTServa control equipment, or only monitor it?

Both are possible, and writes can be disabled per site. A monitoring-only project stays read-only until you decide otherwise.

How do we start?

Request a pilot. Tell us which protocols and devices are on site, and we scope a small pilot that reads your real equipment before anything larger is agreed.

Start With One Site. Prove It on Real Devices.

Tell us which protocols are on site. We will scope a pilot that reads your real devices.